But in next measurement we can see that resistances do not dramatically affect on electric motors performance. You can se that on measurment of resistance where, winding resistances aren't identical.
![3 phase motor winding diagram pdf 3 phase motor winding diagram pdf](https://easa.com/portals/0/Resources/Software/1CircuitWye.png)
Because gap between stator and cover was very small, i decided to do a little bit bigger first coils, and a little bit smaller last coils. This time winding was too big and i couldn't close the cover of motor. Then i decide to make bigger one but i found problem again. I couldn't access to them because other winding were too small. First i made coils too small, and i couldn't insert last coils in slots. I had a lot of problems with winding new winding too. I had a lot of problems with calculation but i solved them and i got same parameters of winding as were on old one. Most time i spent on calculation of new winding. This is all about split phase induction motor.It took me about a week to rewind this motor. The motors are used in mixer grinders, floor polishers.Used in the washing machine, and air conditioning fans.This type of motor is not used for drives that require more than 1 KW because of the low starting torque. This type of motor is cheap and is suitable for easily starting loads where the frequency of starting is limited. Applications of Split Phase Induction Motor The reversal of the motor is possible at the standstill condition only. The direction of the Resistance Start motor can be reversed by reversing the line connection of either the main winding or the starting winding.
#3 phase motor winding diagram pdf full
The starting current of the motor is high about 7 to 8 times the full load value. The maximum torque is about 2.5 times the full load torque at about 75% of the synchronous speed. The starting torque of the resistance start motor is about 1.5 times the full load torque.
![3 phase motor winding diagram pdf 3 phase motor winding diagram pdf](https://easa.com/portals/0/Images/FailuresBrochure/WindingFailure1_web.png)
Here, n 0 is the point at which the centrifugal switch operates. The Torque Speed Characteristic of the Split Phase motor is shown below: This phase difference is enough to produce a rotating magnetic field. The time phase difference ϕ is not 90 degrees, but of the order of 30 degrees. Thus, there exists a time difference between the currents of the two windings. The current in the auxiliary winding I A is approximately in phase with the line voltage. The current in the main winding (I M) lags behind the supply voltage V almost by the 90-degree angle. The phasor diagram of the Split Phase Induction Motor is shown below: Therefore, the relay opens and disconnects the auxiliary winding from the supply, making the motor runs on the main winding only. Thus, the starting winding is in the circuit, and as the motor attains the predetermined speed, the current in the relay starts decreasing. In the starting, the heavy current flows in the circuit, and the contact of the relay gets closed.
#3 phase motor winding diagram pdf series
If the motors are rated about 100 Watt or more, a centrifugal switch is used to disconnect the starting winding and for the smaller rating motors relay is used for the disconnecting of the winding.Ī relay is connected in series with the main winding. At the starting of the motor both the windings are connected in parallel.Īs soon as the motor reaches the speed of about 70 to 80 % of the synchronous speed the starting winding is disconnected automatically from the supply mains. Hence, the starting torque is small, of the order of 1.5 to 2 times the stated running torque. The current in the two windings is not equal as a result, the rotating field is not uniform. A resistor is connected in series with the auxiliary winding.